Pumps Laing DDC

Pumps Laing DDC

Laing DDC pumps were specially designed to be used in a computer water cooling systems that is why this series have typical features:

  • High efficient spherical motor design, ultra quiet, ultra efficient, with an expected service life of well over 50,000 hours at 12 Volt.
  • Highly efficient and dynamically balanced impeller with carbon bearing for smooth ultra quiet operation.
  • High density ceramic bearing ball and graphite impeller bearing cap designed for high efficiency and long life.
  • Embedded microprocessor control is self regulating and available with variable speed with PWM input or dial control (potentiometer) on the pump.
  • Unique patented design has no mechanical seal which is a potential leak path.
  • Unique, low profile space saving design provides easy installation.
  • Pump is designed to be mounted horizontally with discharge.

In Europe these pumps are known under DDC1 and DDC1+ names, while the American market names the same products as DDC 3.2 и DDC 3.2. Since 2009 DDC 3.15 and DDC 3.25 named pumps are appearing in American market. Detailed overview can be found at the end of this article.

Performance graph of Laing DDC pumps

Notwithstanding of its compact size, these pump series have wonderful performance.
Laing DDC Performance

Laing DDC pump arrangement

The arrangement of all Laing pumps is the same; differences can be found in motor hookup or impeller in some cases.
Laing DDC arrangement

Label Decryption of Laing DDC pumps

Laing DDC Label

Detailed measurements of Laing DDC pump series

Detailed measurements of Laing DDC

Installation position

DDC installation position

Laing DDC pump specification spreadsheet

Laing DDC 1 (DDC 3.1) Laing DDC 1Plus (DDC 3.2) Laing DDC 3.15 Laing DDC 3.25
Documents: Datasheet Datasheet
Manual Manual
Performance, l/h: 420 500 300 522
Max Head, Hmax, m: 3.7 4.7 4.2 4.9
Noise level, dBa: 24 ~ 26 30 ~ 32 24 ~ 26 ~ 31
Pipe Connections
Inlet: hose barb 3/8″ (9.5mm) or G1/4 thread
Outlet: hose barb 3/8″ (9.5mm) or G1/4 thread
Rated voltage: 8-13,2 Volt DC (minimum startup Voltage 9 V)
Power consumption, watts: 10 18 13 18
Maximum Working Pressure: 150 kPa (1,5 bar) / 21.75 PSI
Max. Temperature: 60° C / 140° F
Dimensions (in brackets with 1/4″ R male connection). h x l x w, mm : 38(40) x 62(62) x 62(62)
Materials of Construction: Pump Housing – Nylon/PPO
“O” Ring – EPDM or Viton
Impeller – Nylon/PPO
Bearing – Carbon/Allumina Ceramic
All Other Wetted Parts – 316 Stainless Steel or Plastic
Wetted Parts: Stainless steel 1.4571, PPS-GF40, EPDM gasket, Aluminium oxide, carbon; PA6.6 GF35
Acceptable media: Water, Water-/Glycolc Mixtures, other medias on request (check pump performance for mixtures of 20% or more glycole)
Other: Automatic Overload Protection.
The tach signal is an open collector type max 20mA, max 24v, 2 pulses per revolution.
Notes:
Value: 50,41 € 65.54 €

Laing DDC 3.25

  • XS forum member Hondacity made a comparative test of Laing DDC 3.2 and Laing DDC 3.25. In actual loop performance behavior of these two pumps is the same.
  • DDC 3.25 and DDC 3.1 / DDC 3.2 impellers have only color difference
    Laing DDC 3.1 / DDC 3.2 impellers (entirely blue) and Laing DDC 3.25 (red on the inner side)

DDC 3.2 and DDC 3.25 impellers

  • The PCB is the one that Laing 3.1 has, although electronic components in DDC 3.25 differ from DDC 3.1 / DDC 3.2

DDC 3.25 PCBLaing DDC 3.25 PCB

Impeller

All Laing DDC 3-series have the same impeller.

Post Ratings

Vote This Post DownVote This Post Up (+2 rating, 2 votes)
Loading ... Loading ...